GEOMS-TE-UVVIS-DOAS-DIRECTSUN-GAS-005-HONO

Variables

The table below lists the variables that are present in the HARP product that results from an ingestion of GEOMS-TE-UVVIS-DOAS-DIRECTSUN-GAS-005-HONO data.

field name type dimensions unit description
sensor_name string     name of the sensor
site_name string     name of the site at which the sensor is located
datetime double {time} [days since 2000-01-01] mean time of the measurement
datetime_start double {time} [days since 2000-01-01] start time of the measurement
datetime_stop double {time} [days since 2000-01-01] stop time of the measurement
sensor_latitude double   [degree_north] latitude of the sensor
sensor_longitude double   [degree_east] longitude of the sensor
sensor_altitude double   [m] altitude of the sensor relative to the location site
altitude double {time, vertical} [km] effective retrieval altitude
pressure double {time, vertical} [hPa] independent pressure profile
temperature double {time, vertical} [K] independent temperature profile
altitude_bounds double {time, vertical, 2} [km] lower and upper boundaries of the height layers
solar_zenith_angle double {time} [degree] solar astronomical zenith angle
solar_azimuth_angle double {time} [degree] solar azimuth angle
viewing_azimuth_angle double {time} [degree] viewing azimuth angle of the sensor
viewing_zenith_angle double {time} [degree] viewing zenith angle of the sensor
latitude double {time, vertical} [degree_north] latitude of effective air mass at each altitude
longitude double {time, vertical} [degree_east] longitude of effective air mass at each altitude
aerosol_optical_depth double {time} [] aerosol optical depth used for the retrieval
HNO2_column_number_density double {time} [Pmolec cm-2] HNO2 column number density
HNO2_column_number_density_uncertainty_random double {time} [Pmolec cm-2] random uncertainty of the HNO2 column number density
HNO2_column_number_density_uncertainty_systematic double {time} [Pmolec cm-2] systematic uncertainty of the HNO2 column number density
HNO2_column_number_density_apriori double {time, vertical} [Pmolec cm-2] a priori HNO2 column number density
HNO2_column_number_density_avk double {time, vertical} [] averaging kernel for the HNO2 column number density
index int32 {time}   zero-based index of the sample within the source product

Ingestion options

The table below lists the available ingestion options for GEOMS-TE-UVVIS-DOAS-DIRECTSUN products.

option name legal values description
AOD modeled, measured ingest the modeled (default) or measured aerosol optical depth properties

Mapping description

The table below details where and how each variable was retrieved from the input product.

field name mapping description
sensor_name path /@DATA.SOURCE
site_name path /@DATA.LOCATION
datetime path /DATETIME
datetime_start path /DATETIME.START
datetime_stop path /DATETIME.STOP
sensor_latitude path /LATITUDE.INSTRUMENT
sensor_longitude path /LONGITUDE.INSTRUMENT
sensor_altitude path /ALTITUDE.INSTRUMENT
altitude path /ALTITUDE
pressure path /PRESSURE_INDEPENDENT
temperature path /TEMPERATURE_INDEPENDENT
altitude_bounds path /ALTITUDE.BOUNDARIES
solar_zenith_angle path /ANGLE.SOLAR_ZENITH.ASTRONOMICAL
solar_azimuth_angle path /ANGLE.SOLAR_AZIMUTH
viewing_azimuth_angle path /ANGLE.VIEW_AZIMUTH
viewing_zenith_angle path /ANGLE.VIEW_ZENITH
latitude available optional
path /LATITUDE
longitude available optional
path /LONGITUDE
aerosol_optical_depth available optional
condition AOD=modeled or AOD unset
path /AEROSOL.OPTICAL.DEPTH_INDEPENDENT
condition AOD=measured
path /AEROSOL.OPTICAL.DEPTH_ABSORPTION.SOLAR
HNO2_column_number_density path /HONO.COLUMN.ABSORPTION.SOLAR
HNO2_column_number_density_uncertainty_random path /HONO.COLUMN.ABSORPTION.SOLAR_UNCERTAINTY.RANDOM.STANDARD
HNO2_column_number_density_uncertainty_systematic path /HONO.COLUMN.ABSORPTION.SOLAR_UNCERTAINTY.SYSTEMATIC.STANDARD
HNO2_column_number_density_apriori path /HONO.COLUMN.PARTIAL_ABSORPTION.SOLAR_APRIORI
HNO2_column_number_density_avk path /HONO.COLUMN_ABSORPTION.SOLAR_AVK