/** * Sampled_ Value. Context. Reading_ Context_ Code * urn:x-oca:ocpp:uid:1:569261 * Type of detail value: start, end or sample. Default = "Sample.Periodic" * */ export declare type ReadingContextEnumType = 'Interruption.Begin' | 'Interruption.End' | 'Other' | 'Sample.Clock' | 'Sample.Periodic' | 'Transaction.Begin' | 'Transaction.End' | 'Trigger'; /** * Sampled_ Value. Measurand. Measurand_ Code * urn:x-oca:ocpp:uid:1:569263 * Type of measurement. Default = "Energy.Active.Import.Register" * */ export declare type MeasurandEnumType = 'Current.Export' | 'Current.Import' | 'Current.Offered' | 'Energy.Active.Export.Register' | 'Energy.Active.Import.Register' | 'Energy.Reactive.Export.Register' | 'Energy.Reactive.Import.Register' | 'Energy.Active.Export.Interval' | 'Energy.Active.Import.Interval' | 'Energy.Active.Net' | 'Energy.Reactive.Export.Interval' | 'Energy.Reactive.Import.Interval' | 'Energy.Reactive.Net' | 'Energy.Apparent.Net' | 'Energy.Apparent.Import' | 'Energy.Apparent.Export' | 'Frequency' | 'Power.Active.Export' | 'Power.Active.Import' | 'Power.Factor' | 'Power.Offered' | 'Power.Reactive.Export' | 'Power.Reactive.Import' | 'SoC' | 'Voltage'; /** * Sampled_ Value. Phase. Phase_ Code * urn:x-oca:ocpp:uid:1:569264 * Indicates how the measured value is to be interpreted. For instance between L1 and neutral (L1-N) Please note that not all values of phase are applicable to all Measurands. When phase is absent, the measured value is interpreted as an overall value. * */ export declare type PhaseEnumType = 'L1' | 'L2' | 'L3' | 'N' | 'L1-N' | 'L2-N' | 'L3-N' | 'L1-L2' | 'L2-L3' | 'L3-L1'; /** * Sampled_ Value. Location. Location_ Code * urn:x-oca:ocpp:uid:1:569265 * Indicates where the measured value has been sampled. Default = "Outlet" * * */ export declare type LocationEnumType = 'Body' | 'Cable' | 'EV' | 'Inlet' | 'Outlet'; /** * Request_ Body * urn:x-enexis:ecdm:uid:2:234744 * */ export default interface MeterValuesRequest { customData?: CustomDataType; /** * Request_ Body. EVSEID. Numeric_ Identifier * urn:x-enexis:ecdm:uid:1:571101 * This contains a number (>0) designating an EVSE of the Charging Station. ‘0’ (zero) is used to designate the main power meter. * */ evseId: number; meterValue: [MeterValueType, ...MeterValueType[]]; } /** * This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data. */ export interface CustomDataType { vendorId: string; [k: string]: unknown; } /** * Meter_ Value * urn:x-oca:ocpp:uid:2:233265 * Collection of one or more sampled values in MeterValuesRequest and TransactionEvent. All sampled values in a MeterValue are sampled at the same point in time. * */ export interface MeterValueType { customData?: CustomDataType; sampledValue: [SampledValueType, ...SampledValueType[]]; /** * Meter_ Value. Timestamp. Date_ Time * urn:x-oca:ocpp:uid:1:569259 * Timestamp for measured value(s). * */ timestamp: string; } /** * Sampled_ Value * urn:x-oca:ocpp:uid:2:233266 * Single sampled value in MeterValues. Each value can be accompanied by optional fields. * * To save on mobile data usage, default values of all of the optional fields are such that. The value without any additional fields will be interpreted, as a register reading of active import energy in Wh (Watt-hour) units. * */ export interface SampledValueType { customData?: CustomDataType; /** * Sampled_ Value. Value. Measure * urn:x-oca:ocpp:uid:1:569260 * Indicates the measured value. * * */ value: number; context?: ReadingContextEnumType; measurand?: MeasurandEnumType; phase?: PhaseEnumType; location?: LocationEnumType; signedMeterValue?: SignedMeterValueType; unitOfMeasure?: UnitOfMeasureType; } /** * Represent a signed version of the meter value. * */ export interface SignedMeterValueType { customData?: CustomDataType; /** * Base64 encoded, contains the signed data which might contain more then just the meter value. It can contain information like timestamps, reference to a customer etc. * */ signedMeterData: string; /** * Method used to create the digital signature. * */ signingMethod: string; /** * Method used to encode the meter values before applying the digital signature algorithm. * */ encodingMethod: string; /** * Base64 encoded, sending depends on configuration variable _PublicKeyWithSignedMeterValue_. * */ publicKey: string; } /** * Represents a UnitOfMeasure with a multiplier * */ export interface UnitOfMeasureType { customData?: CustomDataType; /** * Unit of the value. Default = "Wh" if the (default) measurand is an "Energy" type. * This field SHALL use a value from the list Standardized Units of Measurements in Part 2 Appendices. * If an applicable unit is available in that list, otherwise a "custom" unit might be used. * */ unit?: string; /** * Multiplier, this value represents the exponent to base 10. I.e. multiplier 3 means 10 raised to the 3rd power. Default is 0. * */ multiplier?: number; }