<?xml version="1.0" encoding="utf-8"?>
<!--Taken from http://manuals.zwaveeurope.com/make.php?lang=en&type=&sku=ZME_05431-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
	<!-- Configuration Parameters -->
	<!--IMPORTANT: Controllers may only allow to configure signed values. 
	    In order to set values in the range  128?255 for parameters 4,  5 and 6 the
	    value sent in the application shall be the desired value minus 256. 
	    For example: to set parameter 4 in Window Blind to 200? sit may be  needed
	    to set a value of 200?256=?56.
	    Similar rule applies to parameter 2: to set values in range 32768?65535
	    use value equal to desired value minus 65536. For example, to set auto
	    switch off period to 10 hours =36000s it may be needed to set a value
	    36000?65536=?29536.-->

	<CommandClass id="112">
		<Value type="list" index="1" genre="config" label="Set LED indication mode" units="" min="1" max="99" value="3" size="1">
			<Item label="Disabled" value="0" />
			<Item label="Show switch/dimmer state / when in motion or inactive (for blinds)" value="1" />
			<Item label="Night mode (inverted switch state)" value="2" />
			<Item label="Operated by Indicator Command Class (default)" value="3" />
			<Item label="Show if not closed (for blinds only)" value="4" />
		</Value>
		<Value type="int" index="2" genre="config" label="Automatically switch off after" units="seconds" min="0" max="65535" value="0">
			<Help>If not zero, automatically switch off/close blind after a user defined time</Help>
		</Value>
		<Value type="list" index="3" genre="config" label="What to do on RF off command" value="0" size="1">
			<Help>If not zero, automatically switch off/close blind after a user defined time</Help>
			<Item label="Switch off (default)" value="0" />
			<Item label="Ignore" value="1" />
			<Item label="Switch on" value="2" />
 	                <Item label="Switch on if load is off else switch off" value="3" />
		</Value>
		<Value type="list" index="4" genre="config" label="Ignore Start Level" value="1" size="1">
			<Help>Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not.</Help>
			<Item label="No" value="0" />
			<Item label="Yes (default)" value="1" />
		</Value>
		<Value type="list" index="5" genre="config" label="Restore switch state after power cycle" value="1">
			<Help>Defines if the switch should restore switch state to the last state prior to device power off (power cycle).</Help>
                        <Item label="No, turn OFF" value="0" />
                        <Item label="Yes (default)" value="1" />
		</Value>
		<Value type="byte" index="10" genre="config" label="Typical click timeout" units="x 10 milliseconds" min="1" max="100" value="50">
			<Help>Typical time used to differentiate click, hold, double and triple clicks.</Help>
		</Value>
		<Value type="list" index="11" genre="config" label="Invert buttons" value="0" size="1">
		  <Item label="No default)" value="0" />
		  <Item label="Yes" value="1" />
		</Value>
		<Value type="list" index="12" genre="config" label="Switch by buttons" value="1" size="1">
			<Help>If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In  this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. </Help>
			<Item label="No" value="0" />
			<Item label="By single press and hold (default)" value="1" />
			<Item label="By double press and hold" value="2" />
		</Value>
		<Value type="list" index="13" genre="config" label="Action on button single press or hold" value="4" size="1">
			<Help>Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. </Help>
			<Item label="Disabled" value="0" />
                        <Item label="Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)" value="4" />
			<Item label="Switch On, Off and dim using Basic Set" value="1" />
			<Item label="Switch All On/Off" value="2" />
                        <Item label="Send Scenes" value="3" />
                        <Item label="Send Predefined Scenes" value="5" />
		</Value>
		<Value type="list" index="14" genre="config" label="Action on button double press or hold" value="0" size="1">
			<Help>Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group.   Switch   All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands.</Help>
			<Item label="Disabled (don't wait for double click,default)" value="0" />
                        <Item label="Switch On/Off and Dim (send Basic Set and Switch Multilevel)" value="4" />
                        <Item label="Switch On, Off and dim using Basic Set" value="1" />
                        <Item label="Switch All On/Off" value="2" />
                        <Item label="Send Scenes" value="3" />
                        <Item label="Send Predefined Scenes" value="5" />
		</Value>
		<Value type="list" index="15" genre="config" label="Send the following Switch All commands" value="1" size="1">
			<Item label="Switch All Off only (default)" value="1" />
			<Item label="Switch All On only" value="2" />
			<Item label="Switch All On and Off" value="255" />
		</Value>
               <Value type="list" index="16" genre="config" label="What to do on button Down press" value="0" size="1">
                        <Item label="Switch off (Default)" value="0" />
                        <Item label="Switch All On only" value="1" />
                        <Item label="Switch on" value="2" />
                </Value>
 
	</CommandClass>

	<!-- Association Groups -->
	<CommandClass id="133">
		<Associations num_groups="3">
			<Group index="1" max_associations="8" label="Group 1 Single press and hold of up/down buttons" auto="false"/>
			<Group index="2" max_associations="8" label="Group 2 Double press and press-hold of up/down buttons" auto="false" />
			<Group index="3" max_associations="8" label="Group 3 Send Reports on switch state change" auto="true"/>
		</Associations>
	</CommandClass>
</Product>