  <CommandClass id="112">
    <Value type="list" genre="config" instance="1" index="1" label="Enable/Disable ALL ON/OFF" value="255" size="1">
      <Help>Activate/Deactive ALL ON/OFF</Help>
      <Item label="ALL ON disabled/ ALL OFF disabled" value="0" />
      <Item label="ALL ON disabled/ ALL OFF active" value="1" />
      <Item label="ALL ON active / ALL OFF disabled" value="2" />
      <Item label="ALL ON active / ALL OFF active" value="255" />
    </Value>
    
    <Value type="list" genre="config" instance="1" index="3" label="Enable/Disable OFF-delay" value="0" size="1">
      <Help>Activate/Deactivate Automatic turning off relay after set time</Help>
      <Item label="Auto OFF disabled for both relays" value="0" />
      <Item label="Auto OFF active only for relay 1" value="1" />
      <Item label="Auto OFF active only for relay 2" value="2" />
      <Item label="Auto OFF active for both relays" value="3" />
    </Value>
    
    <Value type="byte" genre="config" instance="1" index="4" label="Relay: OFF-delay time (10ms)" value="20" size="1">
      <Help>Automatic turning off relay 1 after set time, in 10ms increments (default: 200ms)</Help>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="6" label="Separation of association sending (key 1)" value="0" size="1">
      <Help>Activate/Deactivate association sending for group 1 - Also see param #15</Help>
      <Item label="Map status to all devices in group 1 (default)" value="0" />
      <Item label="Map OFF status to all devices in group 1, Double click on key 1 will send ON to all devices in group 1, all dimmers set to prev.value" value="1" />
      <Item label="Map OFF status to all devices in group 1, Double click on key 1 will send ON to all devices in group 1, all dimmers set to 100%" value="2" />                
    </Value>
    
    <Value type="list" genre="config" instance="1" index="13" label="Inputs behaviour" value="0" size="1">
      <Help>In case of bi-stable switches, define their behaviour (toggle or follow)</Help>
      <Item label="Toggle" value="0"/>
      <Item label="Follow switch contact (closed=ON, open=OFF)" value="1"/>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="14" label="Inputs Button/Switch configuration" value="1" size="1">
      <Help>Binary inputs type configuration</Help>
      <Item label="Mono-stable input (button)" value="0"/>
      <Item label="Bi-stable input (switch)" value="1"/>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="15" label="Dimmer/Roller shutter control" value="0" size="1">
      <Help>Enable/Disable opoeration of dimmer or roller shutter devices associated to group 1.
        Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation</Help>
      <Item label="Disable Dimmer/Roller shutter control" value="0"/>
      <Item label="Enable Dimmer/Roller shutter control" value="1"/>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="16" label="Saving state before power faillure" value="1" size="1">
      <Help>Saving state before power faillure</Help>
      <Item label="State NOT saved at power failure, all outputs are set to OFF upon power restore" value="0"/>
      <Item label="State saved at power failure, all outputs are set to previous state upon power restore" value="1"/>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="30" label="Relay: Response to General Alarm" value="3" size="1">
      <Help></Help>
      <Item label="DEACTIVATION - no response to alarm frames" value="0"/>
      <Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
      <Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
      <Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="31" label="Relay: Response to Water Flood Alarm" value="2" size="1">
      <Help></Help>
      <Item label="DEACTIVATION - no response to alarm frames" value="0"/>
      <Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
      <Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
      <Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>                
    </Value>
    
    <Value type="list" genre="config" instance="1" index="32" label="Relay: Response to Smoke, CO, CO2 Alarm" value="3" size="1">
      <Help></Help>
      <Item label="DEACTIVATION - no response to alarm frames" value="0"/>
      <Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
      <Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
      <Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>
    </Value>
    
    <Value type="list" genre="config" instance="1" index="33" label="Relay: Response to Temperature Alarm" value="1" size="1">
      <Help></Help>
      <Item label="DEACTIVATION - no response to alarm frames" value="0"/>
      <Item label="ALARM RELAY ON - relay will turn ON upon receipt of alarm frame" value="1"/>
      <Item label="ALARM RELAY OFF - relay will turn OFF upon receipt of alarm frame" value="2"/>
      <Item label="ALARM FLASHING - relay will turn ON and OFF periodically (see param.39)" value="3"/>                
    </Value>
    
    <Value type="short" genre="config" instance="1" index="39" label="Active flashing alarm time" value="600" min="1" max="20000" size="2">
      <Help>Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame</Help>
    </Value>
  </CommandClass>
  
  <!-- Association Groups -->
  <CommandClass id="133">
    <Associations num_groups="3">
      <Group index="1" max_associations="16" label="Group 1" auto="false"/>
      <Group index="2" max_associations="16" label="Group 2" auto="false" />
      <Group index="3" max_associations="1" label="Send updates" auto="true"/>
    </Associations>
  </CommandClass>