<?xml version="1.0" encoding="utf-8"?>
<LWM2M  xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="http://openmobilealliance.org/tech/profiles/LWM2M.xsd">
	<Object ObjectType="MODefinition">
		<Name>Power Control</Name>
		<Description1>Description: This Object is used to control a power source, such as a Smart Plug.  It allows a power relay to be turned on or off and its dimmer setting to be control as a % between 0 and 100.</Description1>
		<ObjectID>3312</ObjectID>
		<ObjectURN>urn:oma:lwm2m:ext:3312</ObjectURN>
		<MultipleInstances>Multiple</MultipleInstances>
		<Mandatory>Optional</Mandatory>
		<Resources>
			<Item ID="5850">
				<Name>On/Off</Name>
				<Operations>RW</Operations>
				<MultipleInstances>Single</MultipleInstances>
				<Mandatory>Mandatory</Mandatory>
				<Type>Boolean</Type>
				<RangeEnumeration></RangeEnumeration>
				<Units></Units>
				<Description>This resource represents a power relay, which can be controlled, the setting of which is a Boolean value (1,0) where 1 is on and 0 is off.</Description>
			</Item>
			<Item ID="5851">
				<Name>Dimmer</Name>
				<Operations>RW</Operations>
				<MultipleInstances>Single</MultipleInstances>
				<Mandatory>Optional</Mandatory>
				<Type>Integer</Type>
				<RangeEnumeration>0-100</RangeEnumeration>
				<Units>%</Units>
				<Description>This resource represents a power dimmer setting, which has an Integer value between 0 and 100 as a percentage.</Description>
			</Item>
			<Item ID="5852">
				<Name>On Time</Name>
				<Operations>RW</Operations>
				<MultipleInstances>Single</MultipleInstances>
				<Mandatory>Optional</Mandatory>
				<Type>Integer</Type>
				<RangeEnumeration></RangeEnumeration>
				<Units>sec</Units>
				<Description>The time in seconds that the power relay has been on. Writing a value of 0 resets the counter.</Description>
			</Item>
			<Item ID="5805">
				<Name>Cumulative active power</Name>
				<Operations>R</Operations>
				<MultipleInstances>Single</MultipleInstances>
				<Mandatory>Optional</Mandatory>
				<Type>Float</Type>
				<RangeEnumeration></RangeEnumeration>
				<Units>Wh</Units>
				<Description>The total power in Wh that has been used by the load.</Description>
			</Item>
			<Item ID="5820">
				<Name>Power Factor</Name>
				<Operations>R</Operations>
				<MultipleInstances>Single</MultipleInstances>
				<Mandatory>Optional</Mandatory>
				<Type>Float</Type>
				<RangeEnumeration></RangeEnumeration>
				<Units></Units>
				<Description>The power factor of the load.</Description>
			</Item>
                        <Item ID="5750">
                                <Name>Application Type</Name>
                                <Operations>RW</Operations>
                                <MultipleInstances>Single</MultipleInstances>
                                <Mandatory>Optional</Mandatory>
                                <Type>String</Type>
                                <RangeEnumeration></RangeEnumeration>
                                <Units></Units>
                                <Description>The application type of the sensor or actuator as a string, for instance, “Air Pressure”</Description>
                        </Item>
		</Resources>
		<Description2></Description2>
	</Object>
</LWM2M>